Service Level Objectives (SLOs) and alerting thresholds for Sarvex V1 production monitoring. These rules are based on metrics emitted by the OTEL instrumentation (F-043) wired into all three planes.

Generated from docs/SLO-ALERTING.md in the Sarvex repository — edit the source there, not this page.

Service Level Objectives (SLOs) and alerting thresholds for Sarvex V1 production monitoring. These rules are based on metrics emitted by the OTEL instrumentation (F-043) wired into all three planes.

Overview

Each plane exports metrics via OpenTelemetry to a metrics backend (configured via OTEL_* environment variables). SLOs define acceptable levels of service availability, latency, and error rates. Alerts fire when SLOs are at risk.


Serving Plane SLOs

Responsibilities: UCP profile serving, discovery, pricing, catalog reads, checkout sessions, negotiation.

Availability SLO: 99.9%

Definition: Request success rate (2xx/3xx/4xx) ≥ 99.9% over 30-day rolling window.
Alert condition: Error rate (5xx) > 0.1% over 5-minute window.
Metric: http.server.request.duration (status=5xx)
Action: Page on-call. Check serving-plane logs and Redis serving-cache health.

Latency SLO: p99 < 200ms

Definition: 99th percentile request latency < 200ms for non-checkout requests (checkout sessions are latency-sensitive but exempt from this SLO per architecture).
Alert condition: p99 latency > 400ms sustained for 5 minutes.
Metric: http.server.request.duration (quantile=0.99)
Action: Page on-call. Check database query latency, Redis cache hit rate, downstream connector latency.


Sync Plane SLOs

Responsibilities: Signal ingestion, catalog import, mapping/scoring, feed generation, sweep reconciliation.

Signal Processing SLO: 99% ingestion success

Definition: Successfully ingested signals ≥ 99% of received signals over 1-hour rolling window.
Alert condition: Signal rejection/failure rate > 1% sustained for 10 minutes.
Metric: sync.signal.ingested vs. sync.signal.rejected (by store_id)
Action: Page on-call. Check connector health, catalog-store write availability, event-bus capacity.

Catalog Import SLO: 95% completion rate

Definition: Initiated catalog imports complete successfully ≥ 95% over 24-hour window.
Alert condition: Import failure rate > 5% sustained for 30 minutes.
Metric: sync.import.completed vs. sync.import.failed (by store_id)
Action: Page on-call. Check connector store-API availability, credential rotation, network paths.


Control Plane SLOs

Responsibilities: Console API, operator tooling, task emission, validation.

API Availability SLO: 99.5%

Definition: Console API success rate (2xx/3xx/4xx) ≥ 99.5% over 30-day window.
Alert condition: Error rate (5xx) > 0.5% over 5-minute window.
Metric: http.server.request.duration (path=/v1/*, status=5xx)
Action: Page on-call. Check control-plane service health, database connectivity, event-bus delivery.

Task Emission SLO: 99% delivery

Definition: Tasks raised by domains publish to the event bus successfully ≥ 99% over 1-hour window.
Alert condition: Task emission failure rate > 1% sustained for 5 minutes.
Metric: control.task.emitted vs. control.task.emit_failed (by domain)
Action: Page on-call. Check event-bus capacity (NATS JetStream stream limits), authentication tokens.

Console Responsiveness SLO: p95 < 500ms

Definition: 95th percentile console API latency < 500ms over 1-hour window.
Alert condition: p95 latency > 1000ms sustained for 10 minutes.
Metric: http.server.request.duration (path=/v1/*, quantile=0.95)
Action: Page on-call. Check MongoDB query performance, network paths to merchants’ stores, downstream connector latency.


Cross-Plane SLOs

Event Bus Delivery SLO: 99.99%

Definition: Events published to the bus complete successfully ≥ 99.99% (covers catalog changes, task emission, monitoring signals).
Alert condition: Event publish failure rate > 0.01% sustained for 5 minutes.
Metric: Watermill event-bus publish success/failure counters
Action: Page on-call. Check NATS JetStream health, authentication, consumer backlogs.

Database Availability SLO: 99.9%

Definition: MongoDB writes from all three planes complete successfully ≥ 99.9% over 1-hour window.
Alert condition: Write failure rate > 0.1% sustained for 5 minutes.
Metric: MongoDB driver error counters (by operation type)
Action: Page on-call. Check MongoDB cluster health, network connectivity, replica set status.


Alerting Thresholds (Quick Reference)

Plane Metric Threshold Duration Severity
Serving Error rate (5xx) > 0.1% 5m P1
Serving Latency p99 > 400ms 5m P2
Sync Signal rejection > 1% 10m P1
Sync Import failure > 5% 30m P2
Sync Feed age > 4h 4h P3
Control Error rate (5xx) > 0.5% 5m P1
Control Task emission failure > 1% 5m P1
Control Latency p95 > 1000ms 10m P2
Cross-plane Event bus failure > 0.01% 5m P1
Cross-plane Database write failure > 0.1% 5m P1

Implementation Guide

Export OTEL metrics to Prometheus via the Prometheus exporter. Define alert rules in prometheus-rules.yml:

groups:
  - name: sarvex-serving
    rules:
      - alert: ServingPlaneErrorRateHigh
        expr: 'rate(http_server_request_duration_seconds_bucket{service="serving", status_code=~"5.."}[5m]) > 0.001'
        for: 5m
        annotations:
          summary: "Serving plane error rate > 0.1%"

Custom Integration

If using a different monitoring platform (Datadog, New Relic, etc.):

  1. Configure OTEL exporters to send to your platform via OTEL_EXPORTER_OTLP_* env vars
  2. Map metric names and thresholds (see table above) to your platform’s alert syntax
  3. Ensure on-call routing includes all SLO violations

Monitoring Checklist

  • OTEL metrics flowing to monitoring backend (verify no OTEL exporter errors in logs)
  • Alert policies created and tested in dry-run mode
  • On-call team notified of new alert channels and thresholds
  • Dashboard created for each plane showing current SLO compliance
  • SLO tracking report scheduled (weekly/monthly) to identify trends
  • Runbooks created for top 5 alert types (error-rate, latency, event-bus, database, feed-stale)

SLO Review Cadence

  • Weekly: Triage new alerts, identify patterns
  • Monthly: Review SLO compliance vs. targets, adjust thresholds based on observed baselines
  • Quarterly: Audit SLO definitions against user expectations and business impact

Was this page helpful?